Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f0113-0301xxxx A bus timeout has
occurred on system
CPU 1 PECI.
Error A bus timeout has
been detected.
1. Reseat the microprocessor, and
then restart the server.
2. Replace microprocessor n.
(n = microprocessor number)
806f0123-2101xxxx Reboot of system
initiated by IPMI
Watchdog.
Info A reboot by a
watchdog occurred
has been detected.
No action; information only.
806f0223-2101xxxx Powering off system
initiated by IPMI
Watchdog.
Info A poweroff by
watchdog has been
detected.
No action; information only.
806f0323-2101xxxx Power cycle of
system initiated by
IPMI Watchdog.
Info A power cycle by
watchdog has been
detected.
No action; information only.
806f0413-2582xxxx A PCI PERR has
occurred on system
%1.
(%1 =
CIM_ComputerSystem.
ElementName)
Error A PCI PERR has
occurred.
(Sensor = PCIs)
1. Check the PCI LED. See more
information about the PCI LED in
“Light path diagnostics LEDs” on
page 129.
2. Reseat the affected adapters and
riser cards.
3. Update the server firmware (UEFI
and IMM) and adapter firmware.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
4. Replace the adapters.
5. Replace the riser cards.
Chapter 3. Diagnostics 83