v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
v Go to the IBM support website at http://www.ibm.com/systems/support/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
The OVER SPEC LED on the
light path diagnostics panel is
lit, or the Pwr rail A error has
been recorded in the IMM2
event log.
1. Disconnect the server power cords.
2. (Trained technician only) Remove microprocessor if Pwr Rail A was detected.
3. (Trained service technicians only) Replace the system board (see “Removing
the system board” on page 290 and “Installing the system board” on page 292).
4. Reinstall the component; then, restarting the server. If the Pwr rail A error has
been recorded in the IMM2 event log again, the component that you just
reinstalled is defective. Replace the defective component.
v (Trained technician only) Microprocessor 1 (see “Removing a microprocessor
and heat sink” on page 279 and “Installing a microprocessor and heat sink”
on page 282).
5. Replace the power supply if the OVER SPEC LED on the light path diagnostics
panel is still lit.
The OVER SPEC LED on the
light path diagnostics panel is
lit, or the Pwr rail B error has
been recorded in the IMM2
event log.
1. Disconnect the server power cords.
2. (Trained technician only) Remove microprocessor if Pwr Rail B was detected.
3. Restart the server. If the Pwr rail B error has been recorded in the IMM2 event
log again, (trained technician only) replace the system board (see “Removing
the system board” on page 290 and “Installing the system board” on page 292).
4. Reinstall the component; then, restarting the server. If the Pwr Rail B error has
been recorded in the IMM2 event log again, the component that you just
reinstalled is defective. Replace the defective component.
v (Trained technician only) Microprocessor 2 (see “Removing a microprocessor
and heat sink” on page 279 and “Installing a microprocessor and heat sink”
on page 282).
5. Replace the power supply if the OVER SPEC LED on the light path diagnostics
panel is still lit.
116 IBM System x3650 M4 Type 7915: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3650 M4 Type 7915

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 Type 7915 and is the answer not in the manual?

IBM System x3650 M4 Type 7915 Specifications

General IconGeneral
Form Factor2U Rack
ChipsetIntel C600 series chipset
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
ProcessorUp to two Intel Xeon E5-2600 series processors
MemoryUp to 768GB DDR3 (24 DIMM slots)
StorageUp to 16 x 2.5" or 6 x 3.5" SAS/SATA HDDs or SSDs
RAID SupportRAID 0, 1, 10
NetworkFour integrated Gigabit Ethernet ports
Power SupplyUp to two redundant hot-swap 550 W, 750 W, or 900 W power supplies
Expansion SlotsUp to 7 PCIe 3.0 slots
Storage ControllerServeRAID M5110e
ManagementIntegrated Management Module (IMM) v2