9. If necessary, install the virtual media key.
10. Install the PCI riser-card assemblies and all adapters (see “Installing a PCI
riser-card assembly” on page 219).
11. Install the cover (see “Installing the cover” on page 206).
12. Push the power supplies back into the server.
13. Slide the server into the rack.
14. Reconnect the external cables; then, reconnect the power cords and turn on
the peripheral devices and the server.
Important: Perform the following updates:
v Start the Setup utility and reset the configuration.
– Set the system date and time.
– Set the power-on password.
– Reconfigure the server.
See “Using the Setup utility” on page 301 for details.
v Either update the server with the latest RAID firmware or restore the pre-existing
firmware from a diskette or CD image (see “Updating the firmware” on page
297).
v Update the UUID (see “Updating the Universal Unique Identifier (UUID)” on page
315).
v Update the DMI/SMBIOS (see “Updating the DMI/SMBIOS data” on page 317 ).
Important: Some cluster solutions require specific code levels or coordinated code
updates. If the device is part of a cluster solution, verify that the latest level of code
is supported for the cluster solution before you update the code.
Chapter 5. Removing and replacing server components 295