Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
80010901-0c01xxxx Numeric sensor
Ambient Temp going
high (upper critical)
has asserted.
Error An upper critical
sensor going high
has asserted.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air
from exiting the server.
80010b01-0b01xxxx Numeric sensor
Chroma Temp going
high (upper
non-recoverable)has
asserted.
Error An upper
non-recoverable
sensor going high
has asserted.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
80010b01-0c01xxxx Numeric sensor
Ambient Temp going
high (upper
non-recoverable) has
asserted.
Error An upper
non-recoverable
sensor going high
has asserted.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
81010701-0c01xxxx Numeric sensor
Ambient Temp going
high (upper
non-critical) has
deasserted.
Info An upper
non-critical sensor
going high has
deasserted.
No action; information only.
81010901-0c01xxxx Numeric sensor
Ambient Temp going
high (upper critical)
has deasserted.
Info An upper critical
sensor going high
has deasserted.
No action; information only.
81010b01-0c01xxxx Numeric sensor
Ambient Temp going
high (upper
non-recoverable) has
deasserted.
Info An upper
non-recoverable
sensor going high
has deasserted.
No action; information only.
80010701-1401xxxx
80010701-1402xxxx
Sensor CPU n VR
Temp going high
(upper non-critical)
has asserted.
(n = microprocessor
number)
Warning An upper
non-critical sensor
going high has
asserted.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air
from exiting the server.
80010901-1401xxxx
80010901-1402xxxx
Sensor CPU n VR
Temp going high
(upper critical) has
asserted.
(n = microprocessor
number)
Error An upper critical
sensor going high
has asserted.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air
from exiting the server.
80010b01-1401xxxx
80010b01-1402xxxx
Sensor CPU n VR
Temp going high
(upper
non-recoverable) has
asserted.
(n = microprocessor
number)
Error An upper
non-recoverable
sensor going high
has asserted.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
48 IBM System x3650 M4 Type 7915: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3650 M4 Type 7915

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 Type 7915 and is the answer not in the manual?

IBM System x3650 M4 Type 7915 Specifications

General IconGeneral
BrandIBM
ModelSystem x3650 M4 Type 7915
CategoryServer
LanguageEnglish

Related product manuals