Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f060d-0400xxxx
806f060d-0401xxxx
806f060d-0402xxxx
806f060d-0403xxxx
806f060d-0404xxxx
806f060d-0405xxxx
806f060d-0406xxxx
806f060d-0407xxxx
806f060d-0408xxxx
806f060d-0409xxxx
806f060d-040axxxx
806f060d-040bxxxx
806f060d-040cxxxx
806f060d-040dxxxx
806f060d-040exxxx
806f060d-040fxxxx
Array %1 has failed.
(%1 =
CIM_ComputerSystem.
ElementName)
Error An array is in a
failed state.
(Sensor = Drive n
Status)
(n = hard disk drive
number)
1. Make sure that the RAID adapter
firmware and hard disk drive
firmware is at the latest level.
2. Make sure that the SAS cable is
connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is
indicated by a lit status LED.
806f070d-0400xxxx
806f070d-0401xxxx
806f070d-0402xxxx
806f070d-0403xxxx
806f070d-0404xxxx
806f070d-0405xxxx
806f070d-0406xxxx
806f070d-0407xxxx
806f070d-0408xxxx
806f070d-0409xxxx
806f070d-040axxxx
806f070d-040bxxxx
806f070d-040cxxxx
806f070d-040dxxxx
806f070d-040exxxx
806f070d-040fxxxx
The Drive n Status
rebuilt has been in
progress.
(n = hard disk drive
number)
Info The Drive n has
rebuilt in progress.
(n = hard disk drive
number)
No action; information only.
80 IBM System x3650 M4 Type 7915: Problem Determination and Service Guide