Section 2 - Product Information
PRODUCT INFO
16 Installation and Servicing
Table 7 Single Zone Pre-plumbed Cylinder with Integrated Buffer
performance within a residential environment
Figure 13. Plan View - PP Single Zone Bu - 550 mm
Figure 14. Plan View - PP Single Zone Bu - 630 mm
1
2
3
6
7
8
9
10
O
v
e
r
h
e
a
t
T
h
e
r
m
o
s
t
a
t
C
o
n
t
ro
l
T
h
e
rm
i
s
t
or
CYLINDER HOT OUTLET
4
5
CONTROL PANEL
MINIMUM
< - CLEARANCE - >
FOR REMOVAL
OF PTRV
ALLOW EXTRA 200MM
< - - - CLEARANCE FOR FILTER
& SPANNER ACCESS
<- MINIMUM WIDTH = 705 mm ->
<
-
M
I
N
I
M
U
M
D
E
P
T
H
=
7
1
0
m
m
-
>
All pipe holes are optional.
All pipe hole sizes are dictated by the
property / design. Therefore are a general indication.
The template is a general guide for installation
rather than a rule that must be followed without
deviation.
Dual Zone Version
Number
Description
Size (mm)
1
Heat Pump Flow
28
2
Heat Pump Return
28
3
Central Heating Return
22/28
4
Central Heating Return
22/28
5
Central Heating Flow Z1
22/28
6
Central Heating Flow Z2
22/28
7
Tundish Outlet 22
8
Balanced Cold Feed
22/28
9
Mains Cold Supply
22/28
10
Hot Water Feed
22/28
Single Zone Version
Number
Description
Size (mm)
1
Heat Pump Flow
28
2
Heat Pump Return
28
3
N/A N/A
4
Central Heating Return
22/28
5
Central Heating Flow
22/28
6
N/A N/A
7
Tundish Outlet 22
8
Balanced Cold Feed
22/28
9
Mains Cold Supply
22/28
10
Hot Water Feed
22/28
1
2
3
6
7
8
9
10
O
v
e
r
h
e
a
t
T
h
e
r
m
o
s
t
a
t
C
on
t
ro
l
T
h
e
rm
i
s
t
o
r
CYLINDER HOT OUTLET
4
5
CONTROL PANEL
MINIMUM
< - CLEARANCE - >
FOR REMOVAL
OF PTRV
ALLOW EXTRA 200MM
< - - - CLEARANCE FOR FILTER
& SPANNER ACCESS
236399
<- MINIMUM WIDTH = 765 mm ->
<
-
M
I
N
I
M
U
M
D
E
P
T
H
=
7
9
0
m
m
-
>
All pipe holes are optional.
All pipe hole sizes are dictated by the
property / design. Therefore are a general indication.
The template is a general guide fo
r installation
rather than a rule that must be followed without
deviation.
Dual Zone Version
Number
Description
Size (mm)
1
Heat Pump Flow
28
2
Heat Pump Return
28
3
Central Heating Return
22/28
4
Central Heating Return
22/28
5
Central Heating Flow Z1
22/28
6
Central Heating Flow Z2
22/28
7
Tundish Outlet
22
8
Balanced Cold Feed
22/28
9
Mains Cold Supply
22/28
10
Hot Water Feed
22/28
Single Zone Version
Number
Description
Size (mm)
1
Heat Pump Flow
28
2
Heat Pump Return
28
3
N/A N/A
4
Central Heating Return
22/28
5
Central Heating Flow
22/28
6
N/A N/A
7
Tundish Outlet 22
8
Balanced Cold Feed
22/28
9
Mains Cold Supply
22/28
10
Hot Water Feed
22/28
HP290 Single Zone Pre-plumbed Cylinder with Integrated Buer
General Descripon
180, 210, 250 & 300 litre; 550mm & 630mm diameter; single coil cylinders intended for coupling with a range of heat pumps
5kW to 14kW; Pre-plumbed and pre-wired including control box. Intended for a single zone heang system installaon. These
products incorporate a buer which increases system volume and decouples the heat pump from the central heang zone. It
is possible to upgrade this product to a dual zone at a later date.
Assembly Model code/number
HP290 DHW pre-plumbed
cylinder 180L, control box &
buer 1-zone
HP290 DHW pre-plumbed
cylinder 210L, control box &
buer 1-zone
HP290 DHW pre-plumbed
cylinder 250L, control box &
buer 1-zone
HP290 DHW pre-plumbed
cylinder 300L, control box &
buer 1-zone
Product Code
239599 239601 239603 239605
Cylinder model code/number
IDEPLUHP180DUOPPSZ IDEPLUHP210DUOPPSZ IDEPLUHP250DUOPPSZ IDEPLUHP300DUOPPSZ
Energy Eciency Class B B B B
Heat Loss
Was 49 55 62 68
kWh/24h 1.18 1.33 1.49 1.63
Capacity (DHW content) Litres 171 199 239 287
Volume heated by immersion heater Litres 158 189 218 267
Weight Empty kg 64.6 68.6 77 87
Weight Full kg 305.6 337.4 379 437.5
Pressure Reducing valve seng bar 3 3 3 3
Expansion relief valve seng bar 4.5 4.5 4.5 4.5
Temperature seng of TPRV °C 95 95 95 95
Pressure seng of TPRV bar 6 6 6 6
Potable Expansion Vessel size. Litres 18 24 24 35
Expansion Vessel charge bar 3 3 3 3
Overall Width mm
644 644 705 705
Overall Height mm
1907 2095 1908 2128
Overall Depth mm
702 702 780 780
Cylinder Diameter mm A 550 A 550 A 630 A 630
DHW outlet mm
B 1888 B 2076 B 1889 B 2109
Cylinder Height mm C 1829 C 2017 C 1829 C 2049
TPRV port mm D 1586 D 1774 D 1572 D 1792
Manual reset overheat thermostat pocket mm E 1151 E 1151 E 1151 E 1151
Primary ow mm F 742 F 742 F 742 F 742
Secondary return port mm G - G 1664 G 1491 G 1678
Thermistor pocket mm H 1109 H 1172 H 1101 H 1174
Primary return mm J 117 J 117 J 82 J 82
Immersion heater pocket mm K 744 K 744 K 736 K 736
Cold Water Inlet mm L 1810 L 2000 L 1796 L 2016
Cylinder Drain mm M 744 M 744 M 736 M 736
CH1 Flow mm N 118 N 118 N 83 N 83
CH2 Flow (n/a to SZ version) mm P 118 P 118 P 83 P 83
CH Return mm Q 118 Q 118
Q 83 Q 83
Buer Connecons mm R 375 R 375 R 340 R 340
Buer Inspecon mm S 360 S 360 S 325 S 325
Buer Drain mm T 221 T 221 T 219 T 219
Primary heat exchanger surface area m
2
2.5 2.5 2.5 3.0
Primary heat exchanger capacity Litres 8.5 10.6 8.5 10.6
Buer Capacity Litres 70 70 63.5 63.5
HWA Heat pump Test
Primary heat exchanger thermal rang kW 17.8 14.5 23.6 14.3
Heat up me from 10°C to 50°C min 22.2 32.7 26.6 44.1
V40 Litres 185.5 224.3 260.2 295.8
BS EN 12897 Test
Primary heat exchanger thermal rang kW 35.1 37.2 37 39.2
Primary heat exchanger pressure loss bar 0.08 0.05 0.05 0.04
Heat up me from 10°C to 60°C min 14.5 16.4 20.3 21.8
V40 Litres 241.5 288.4 354.5 402.2
Revision Level D8.2 D8.2 D8.2 D8.2