IDS X-Series Installer Manual 700-398-02H Issued July 2013
LOCATION 449 – 454 Zone Expander Output OFF Time (default = 2400)
Enter a 4-digit time, [HHMM], for each of the 6 zone expander outputs and program as an 8-digit
string, followed by the [*] key.
[INSTALLER CODE] [*] [LOCATION] [*] [OUTPUT NO.] [*] [HHMM] [*]
The valid data range is: 00h00m – 23h59m, with 24h00m to disable.
Output no. is: 1-2.
Refer to Using Sub-locations to see how to scroll through sub-location using the [*] key.
LOCATION 457 Keypad Output OFF Time (default = 2400)
Enter a 4-digit time, [HHMM], for each of the 8 keypad outputs and program as a 32-digit string,
followed by the [*] key.
[INSTALLER CODE] [*] [4] [5] [7] [*] [OUTPUT NO.] [*] [HHMM] [*]
The valid data range is: 00h00m – 23h59m, with 24h00m to disable.
Output no. is: 1-8.
Output Scheduling On/Off Days - Advanced
Outputs can be scheduled to set and reset at specified times on specific days of the week. To disable scheduling
of an output ensure that all “days” are deselected.
LOCATIONS 458 – 498 Output On/Off Days
The on/off days for the outputs, to turn on or off, in Table 39 can be programmed by using the
values in Table 38.
Table 38: Output Scheduling On/Off Days Data
Table 39: Outputs per Location
Zone Expander 5, Output 1
Zone Expander 5, Output 2
Zone Expander 6, Output 1
Zone Expander 6, Output 2
Zone Expander 1, Output 1
Zone Expander 1, Output 2
Zone Expander 2, Output 1
Zone Expander 2, Output 2
Zone Expander 3, Output 1
Zone Expander 3, Output 2
Zone Expander 4, Output 1
Zone Expander 4, Output 2