IDS X-Series Installer Manual 700-398-02H Issued July 2013
LOCATION 21 Keypad Lockout Time (default = 0030)
The value determines the period of time for which the keypad will remain locked out if the keypad
lockout count programmed into location 20 has been exceeded. After this period has elapsed, a locked out
keypad will return to an unlocked state. Keypad lockout is enabled by partition; refer to locations 221-228 for
extended partition options, but this period applies to all partitions.
To program the time into this location, the format is [MMSS].
[INSTALLER CODE] [*] [2] [1] [*] [MMSS] [*]
The valid data range is: 00m01s – 59m59s.
LOCATION 22 Keypad Sleep Delay (default = 0500)
This location sets the time out period before the keypad enters sleep mode. After the delay period,
if there is no keypad activity (on any keypad) the backlighting and all other status and alarm LEDs will turn off.
The following events will bring a keypad out of sleep mode: Zone violations/restorals, Tamper
violations/restorals, or key presses.
To program the time into this location, the format is [MMSS].
[INSTALLER CODE] [*] [2] [2] [*] [MMSS] [*]
The valid data range is: 00m01s – 59m59s.
LOCATION 23 User, Installer & Maintenance Code - Number of Digits (default = 4)
This location determines whether user, installer and maintenance codes are 4 or 6 digits in length.
The value programmed into this location has no effect on the download code, which is always 4-digits in length.
Refer to Table 12 to view the defaults for 4-digit and 6-digit codes.
If the code length is changed from 6 to 4, then all user codes are automatically set to their default values as per
Table 12. This is to avoid duplicate codes being inadvertently created when they have the same first 4 digits.
Table 12: Number of Digits Data
[INSTALLER CODE] [*] [2] [3] [*] [NUMBER OF DIGITS] [*]
The valid data range is either 4 or 6.
LOCATION 24 Number of Account Code Digits (default = 4)
This location sets the account code length to either 4 or 6 digits. If the length of your account codes
is 4 digits and then they are changed to 6 digits, the last two digits will be set to 0.
[INSTALLER CODE] [*] [2] [4] [*] [NUMBER OF DIGITS] [*]
The valid data range is: 4 or 6.
Daylight Savings
LOCATION 25 Month to Start Daylight Saving (default = 0)
Select the month for Daylight Saving to commence, as per Table 13.
Table 13: Month Data
[INSTALLER CODE] [*] [2] [5] [*] [MONTH] [*]
NOTE: If this location is disabled, then by default, locations 26 and 27 will also be disabled. This means that
even if you put values into locations 26 and 27, daylight savings will not commence.