IDS X-Series Installer Manual 700-398-02H Issued July 2013
Event Reporting Options - Advanced
The following locations from 501-588 enable disable the reporting of events programmed into locations 300-
373. If a reporting code has been programmed, and the reporting of that code is not enabled here – then the
reporting code will not report.
Note: Default values indicated in the default column
The valid data range in location 501 to 589 options 1 to 8, Actions, and options 9 to 16, Reporting Pair are:
Valid data range options 1 to 8
Valid data range options 9 to 16
LOCATIONS 501 – 564 Split Reporting Zones 1 - 64
Locations 501 (zone 1) – 564 (zone 64) represent a bitmap of 64 split reporting zone locations.
Table 40: Split Reporting Zones Bitmap Data
Zone alarm restore reporting
Disable zone bypass reporting
Zone tamper restore reporting
Zone swinger shutdown reporting
Zone swinger shutdown restore reporting
NOTE: See Communications Setup - Advanced.
LOCATION 571 Global Split Reporting 1
Table 41: Global Split Reporting 1 Bitmap Data
Communication fail reporting *
Telephone line tamper reporting
Panel low battery fail reporting
Aux 12V fuse fail reporting
* The reporting code is only supported by Contact ID or SIA, and thus will not be reported if any other format
has been selected.
LOCATION 572 Global Split Reporting 2
Table 42: Global Split Reporting 2 Bitmap Data
Bus-wired peripheral tamper reporting
Bus-wired peripheral fail reporting
Bus-wired peripheral low battery reporting *
Wireless Detector Battery Low
Wireless Detector Supervision fail
Wireless Receiver Signal Jammed
Wireless Detector RSSI Low