IDS X-Series Installer Manual 700-398-02H Issued July 2013
59
Event Reporting Options - Advanced
The following locations from 501-588 enable disable the reporting of events programmed into locations 300-
373. If a reporting code has been programmed, and the reporting of that code is not enabled here then the
reporting code will not report.
Note: Default values indicated in the default column
The valid data range in location 501 to 589 options 1 to 8, Actions, and options 9 to 16, Reporting Pair are:
Valid data range options 1 to 8
Valid data range options 9 to 16
ON = Enable
ON = Telephone module 2
OFF = Disable
OFF = Telephone module 1
LOCATIONS 501 564 Split Reporting Zones 1 - 64
Locations 501 (zone 1) 564 (zone 64) represent a bitmap of 64 split reporting zone locations.
Table 40: Split Reporting Zones Bitmap Data
LED
Default
Action
LED
Default
Reporting Pair
1
ON
Zone alarm reporting
9
OFF
Telephone module 1
2
OFF
Zone alarm restore reporting
10
OFF
Telephone module 1
3
OFF
Disable zone bypass reporting
11
OFF
Telephone module 1
4
OFF
Zone force arm reporting
12
OFF
Telephone module 1
5
OFF
Zone tamper reporting
13
OFF
Telephone module 1
6
OFF
Zone tamper restore reporting
14
OFF
Telephone module 1
7
OFF
Zone swinger shutdown reporting
15
OFF
Telephone module 1
8
OFF
Zone swinger shutdown restore reporting
16
OFF
Telephone module 1
NOTE: See Communications Setup - Advanced.
LOCATION 571 Global Split Reporting 1
Table 41: Global Split Reporting 1 Bitmap Data
LED
Default
Action
LED
Default
Reporting Pair
1
ON
AC fail reporting
9
OFF
Telephone module 1
2
OFF
Communication fail reporting *
10
OFF
Telephone module 1
3
ON
Telephone line tamper reporting
11
OFF
Telephone module 1
4
ON
Siren fail reporting
12
OFF
Telephone module 1
5
ON
Panel low battery fail reporting
13
OFF
Telephone module 1
6
ON
Aux 12V fuse fail reporting
14
OFF
Telephone module 1
7
OFF
Installer Reset Required
15
OFF
Telephone module 1
8
ON
Box tamper reporting
16
OFF
Telephone module 1
* The reporting code is only supported by Contact ID or SIA, and thus will not be reported if any other format
has been selected.
LOCATION 572 Global Split Reporting 2
Table 42: Global Split Reporting 2 Bitmap Data
LED
Default
Action
LED
Default
Reporting Pair
1
ON
Bus-wired peripheral tamper reporting
9
OFF
Telephone module 2
2
ON
Bus-wired peripheral fail reporting
10
OFF
Telephone module 2
3
OFF
Bus-wired peripheral low battery reporting *
11
OFF
Telephone module 1
4
OFF
Wireless Detector Battery Low
12
OFF
Telephone module 1
5
OFF
Wireless Detector Supervision fail
13
OFF
Telephone module 1
6
OFF
Wireless Receiver Signal Jammed
14
OFF
Telephone module 1
7
OFF
Wireless Detector RSSI Low
15
OFF
Telephone module 1
8
ON
AC Restored
16
OFF
Telephone module 1