RDX A8 User and Service Guide — Version 1.0
2. Product installation
a. General installation considerations
This section provides instructions for installing the RDX A8.
i. Selecting a location
Select a location that meets the following criteria:
Criteria Definition
Mounting orientation Horizontal only-either sitting on a table top or mounted in a 19” equipment
rack via the included rack mount ears. The RDX A8 weighs 15.7 lbs (7.1 kg)
when fully populated with cartridges and must be placed on or mounted
in a system capable of supporting this weight
Rack requirements Standard EIA rack 2U space
Room temperature
Operating
Non-operating
+10° – +40° C, gradient 10°C/hour
- 30° – +60° C, gradient 20°C/hour
Power source 100-240 VAC input voltage
50-60 Hz line frequency
1.2-0.6 A
Locate the RDX A8 within 6 ft. of an AC outlet.
The AC power cord is the RDX A8 main AC disconnect device and
must be easily accessible at all times.
Air quality Place the RDX A8 in an area with minimal sources of particulate generation.
Excessive dust and debris can damage the system.
Avoid locating the unit in areas near frequently used doors and walkways,
smoke-filled rooms, or areas where it may easily be knocked over.
Humidity
Operating
Non-operating
20 – 80 % non-condensing
20 – 90 % non-condensing
For further information, see section Physical Specification.