74
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
Error
Code
Anomaly signalled Cause Appliance status / Solution
96 Clogged ue
is occurs in the event an obstruction is detected in the
ue system.
e appliance does not start (1). If
normal conditions are restored the
boiler restarts without having to be
reset
If error 96 appears aer the Techni-
cian has made changes on the "ue"
parameters, it is necessary to perform
a "quick calibration".
97
Timed
Service operation
request warning
e time range envisaged by the Assistance Centre for
scheduled maintenance has expired.
Error only displayed on remote device
(if present) (1)
98
Block - maximum no.
of soware errors
e maximum number of soware errors possible has been
reached.
Press the Reset button (1)
138
Screed heater in
progress
Signalling to remote screed heater function devices (except
CAR
V2
).
(1)
139
Deaeration in
progress
Signalling to remote venting function devices (except
CAR
V2
).
(1)
146
System pressure too
high
e system pressure sensor has detected very high pres-
sure.
e boiler keeps working (1) (2)
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Service Centre)
(2) e anomaly can only be veried in the list of errors in the “Information” menu
(3) Error displayed only on CAR
V2
(4) Error displayed only on Anomalies log