1.16 CONCENTRIC HORIZONTAL KIT INSTALLATION
Type C conguration, sealed chamber and fan assisted
e position of the terminal (in terms of distances from openings, overlooking buildings, oor, etc.) must be in compliance with the reg-
ulations in force.
is terminal is connected directly to the outside of the building for air intake and ue gas exhaust.
e horizontal kit can be installed with the rear, right side, le side or front outlet.
For installation with frontal outlet, one must use the xing plate and a concentric bend coupling in order to ensure sucient space to
carry out the tests required by law upon commissioning.
External grid
Both the Ø 60/100 and Ø 80/125 intake/exhaust terminal, if properly installed, is pleasant to look at on the outside of the building.
Make sure that the external silicone wall sealing plate is properly inserted in the wall.
For correct functioning of the system the terminal with grid must be installed correctly ensuring that, the "high" indication
present on the terminal is respected on installation.