100 ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual
Chapter 7—Commands
SA – Setup Adjust
Description is command is used to control the activation and storage of
setup commands / values.
Syntax SAp
1
Parameters p
1
Setup Adjust value:
0 All setup commands remain active and values are saved when
changed. The printer will use stored setup values (Default).
1 All setup parameters are locked and commands will be ignored. The
printer will use previously stored setup values.
2 All setup commands within forms will be ignored.
Remarks e SA command affects the following setup commands: R, r,
D, j, J, q, Q, S, Z, and SPC. e current SA value is stored in
Flash memory and printed on the test label.
Example SA2 :All of the commands listed above that are called
within forms will be ignored.