46 ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual
Chapter 7—Commands
b – Data Matrix
Description e following Data Matrix specific options should append the
general part of the two-dimensional code command (indicated by
italic characters, see b command, general part).
Syntax bp
1
,p
2
,p
3
,[P
4
,"DATA"]
Parameters P
4
Narrow bar from 1 to 15.
"DATA" Represents a fixed data field, maximum 125 characters long.
Example N ↵
b40,80,D,5,"123456789012345678901234567890→
→1234567890123456789012345678901234567890→
→12345678901234567890" ↵
P1 ↵