78 ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual
Chapter 7—Commands
JB – Disable Top of Form Backup
Description is command disables automatic top of form backup of the
media.
Syntax JB
Remarks Top of form backup is used in connection with the j command,
which makes the printer feed out an extra amount of media after
printing the label, so as to allow the media to be torn or peeled
off properly. It does not work with a cutter.
By default, the media is pulled back before printing the first label
in next batch as to allow the printing to start at the top of the
label, see JF command.
e JB command will disable this function, that is any j com-
mand will be ignored, and the printer will stop feeding when
the end of the label becomes aligned with the printhead’s dot
line. However, the j command is kept stored in memory and can
be enabled again using a JF command. To disabled top of form
baclup with a cutter, first send an O command followed by a JB
command.
Example JB :Disables top of form backup

Table of Contents

Other manuals for Intermec EasyCoder PD4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PD4 and is the answer not in the manual?

Intermec EasyCoder PD4 Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder PD4
CategoryLabel Maker
LanguageEnglish

Related product manuals