ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual 15
Chapter 3—Setting Up the Printer
Some commands may also affect the values of other command, for
example if a configuration label is printed (see U and UP commands),
the print direction is reset to ZT, and if an R Reference Point command
is executed, the label width (see q command) will be changed.
Example
Let us assume that we will use an EasyCoder PD4 for direct thermal
printing. We will print full width ermal Top labels in the peel-off
mode without using the label taken sensor. e default communication
setup and character set are acceptable.
us, a few setup parameters should be changed in the Direct Mode:
Density from 10 to 8
Media feed adjustment from 136 to 110
Label Taken Sensor from enabled to disabled
Enter the following commands:
Command Explanation
CR/LF to start command structure
D8
Set density
j110
Set media feed adjustment for peel-off
operation
ON
Disable label taken sensor

Table of Contents

Other manuals for Intermec EasyCoder PD4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PD4 and is the answer not in the manual?

Intermec EasyCoder PD4 Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder PD4
CategoryLabel Maker
LanguageEnglish

Related product manuals