ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual 15
Chapter 3—Setting Up the Printer
Some commands may also affect the values of other command, for
example if a configuration label is printed (see U and UP commands),
the print direction is reset to ZT, and if an R Reference Point command
is executed, the label width (see q command) will be changed.
Example
Let us assume that we will use an EasyCoder PD4 for direct thermal
printing. We will print full width ermal Top labels in the peel-off
mode without using the label taken sensor. e default communication
setup and character set are acceptable.
us, a few setup parameters should be changed in the Direct Mode:
• Density from 10 to 8
• Media feed adjustment from 136 to 110
• Label Taken Sensor from enabled to disabled
Enter the following commands:
Command Explanation
↵
CR/LF to start command structure
D8
↵
Set density
j110
↵
Set media feed adjustment for peel-off
operation
ON
↵
Disable label taken sensor