154 ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual
Appendix A — Error-Handling
Error Replies Table
Error Displayed Error Message
or (Mode Status)
Error Response depending on cmd US/UN Response
at cmd
^ee
Code Type command US:
reporting on
command UN: report-
ing off
LED Serial LED Serial
00 No Error GRN - GRN - 00<CRLF>
01 A Syntax error RED <NAK>01[XOFF] GRN - 01<CRLF>
02 B Object exceeds image buffer
border
RED <NAK>02[XOFF] RED [XOFF] 02<CRLF>
03 A Data length error RED <NAK>03[XOFF] GRN - 03<CRLF>
04 A Insufficient memory to store
Data
RED <NAK>04[XOFF] GRN - 04<CRLF>
05 A Memory configuration error RED <NAK>05[XOFF] GRN - 05<CRLF>
7 C Out of media RED <NAK>07Pnnn[XOFF]
(nnn = numbers of
remaining labels)
RED [XOFF] 07<CRLF>
08 A Form or image name
duplicate
RED <NAK>08[XOFF] GRN - 08<CRLF>
09 A Form or image not found RED <NAK>09[XOFF] GRN - 09<CRLF>
11 D Print head lifted RED <NAK>11[XOFF] RED [XOFF] 11<CRLF>
13 E Label taken sensor waiting - <NAK>13[XOFF]
(if command USE has
been preceded)
- - 13<CRLF>
16 A No form was retrieved before
“? “
RED <NAK>16[XOFF] GRN - 16<CRLF>
17 C Out of ribbon RED <NAK>17Rnnn[XOFF]
(nnn = numbers of
remaining labels)
RED [XOFF] 17<CRLF>
50 A Does not fit in area specified RED <NAK>50[XOFF] GRN - 50<CRLF>
51 A Data length too long RED <NAK>51[XOFF] GRN - 51<CRLF>
62 D High print head temperature
(WAIT)
BLNK
RED
<NAK>62[XOFF] BLNK
RED
[XOFF] 62<CRLF>
71 F Default Setup retrieved
(RESET)
GRN - GRN [XOFF] 71<CRLF>
72 F Flashing not completed
(RESET)
RED <NAK>72[XOFF] RED [XOFF] 72<CRLF>
73 F Download error (RESET) RED <NAK>73[XOFF] RED [XOFF]
73<CRLF>
81 B Cutter jammed or not
installed
BLNK
RED
<NAK>81[XOFF] BLNK
RED
[XOFF] 81<CRLF>
89 G (Dump Mode) GRN <NAK>89 XOFF] GRN - 89<CRLF>