Y – Serial Port Setup
Description is command is used to establish the communication param-
eters of the serial RS-232 port.
Syntax Yp
1
,p
2
,p
3
,p
4
Parameters p
1
Baud rate:
48 4,800 bps
96 9,600 bps
19 19,200 bps
38 38400 bps
p
2
Parity:
O Odd. (O is uppercase o character; ASCII 79 dec.).
E Even.
N None.
p
3
Number of data bits:
7 7 data bits.
8 8 data bits.
p
4
Number of stop bits:
1 1 stop bit.
2 2 stop bits.
Remarks After receiving this command, the printer will automatically reset
its communication on the serial RS-232 communication port.
ere are no such parameters for the USB port.
By default, the printer is set for 9600 baud, no parity, 8 data bits,
1 stop bit.
XON/XOFF handshaking is always used. e printer sends
XOFF when an error occurs. RTS/CTS is not supported
If the current communication setup is not known, it can be
checked by printing a test label (see Chapter 1).
Example Y19,O,7,1 :Sets 19,200 baud, odd parity,
7 data bits, 1 stop bit

Table of Contents

Other manuals for Intermec EasyCoder PD4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PD4 and is the answer not in the manual?

Intermec EasyCoder PD4 Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder PD4
CategoryLabel Maker
LanguageEnglish

Related product manuals