ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual 115
Chapter 7—Commands
US – Enable Error Reporting
Description is command is used to enable the printers status reporting
feature with optional direct recovery.
Syntax US[A][B][E]
Parameters A If any error of type A occurs, it will be directly recovered and continue in normal
mode. No stop for recovery, often performed with FEED key.
B If any error of type B occurs, it will be directly recovered and continue in normal
mode. No stop for recovery, often performed with FEED key.
E Error 13 LTS reply control (label taken sensor). Returns error 13 if LTS detects a
label before and after printing.
Remarks Any or all parameters can be activated at the same time. Refer to
Appendix A for information on error types.
Parameters are saved in the Flash memory.
e format of the error messages is controlled by the eR com-
mand.
Example
Command Reply
1
Comment
USABE
<ACK> Activate all error flags
eRQ,6,R
(no reply)
Setup User-Defined Error/Status Character control to
Q for <XOFF> and <R> for <XON>
N
(no reply)
Clear image buffer and errors
AA
(no reply)
Erroneous command type A; Syntax error
P
<NAK>01Q Print image buffer with error 01
R Direct recovery error 01 (type A) and continue
1
/. Reply only works on serial and USB ports.

Table of Contents

Other manuals for Intermec EasyCoder PD4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PD4 and is the answer not in the manual?

Intermec EasyCoder PD4 Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder PD4
CategoryLabel Maker
LanguageEnglish

Related product manuals