152 ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual
Appendix A — Error-Handling
Error Types
Classified types of error & status codes for the Error Replies table later in
this appendix.
Type Feature Generates Recovered by
A Minor Error
of command
sequences and
similar.
At Error reporting (cmd
US): Sets error on print
command and sets Error
LED to solid red.
At no Error reporting (cmd
UN): sets Ready LED to
green at print command
At Error reporting (cmd
US):
Press Feed key orsend Reset
command
^@. Also see cmd
USA.
At No Error reporting (cmd
UN): No recover necessary,
already done.
B Print Stop-
ping Error.
Sets Error LED to solid red Feed Key or command Reset
^@.See also command USB.
C Paper End
Stopping
Error.
Sets Error LED to solid red
at print.
Load new media and press
Feed key or send Reset com
-
mand
^@.
D Error of
printing func
-
tionality and
status.
Sets Error LED directly to
red, sometimes blinking.
Manual or automatic (tem
-
perature lowered) measure or
send Reset command
^@.
E Status
changes.
No LED change. No recover necessary/Delete
Label from LTS. See also com-
mand
USE.
F Unrecoverable
Error.
Sets Error LED directly to
red.
Power Off/Power On or send
Reset command ^@.
G Various modes Not applicable