ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual 151
Appendix A — Error-Handling
Error recovery/output
e normal action at any error is to stop in a waiting loop to recover the
error feature. At this “Error Waiting Loop” only command ^ee and ^@
can be performed and executed.
e error recovery, often performed by pressing the FEED key, releases
the error and sends recovery information on the serial line (RS-232 or
USB), normally <XON>.
See also commands USA or USB for direct recovery.
Error-handling commands
US[A][B][E] Optional Error Reporting
UN No Error Reporting
eR User Defined Error/Status Character Control
^ee Error Report - Immediate
^@ Reset