EasyManuals Logo

Intermec EasyCoder PD4 Programmer's Reference Manual

Intermec EasyCoder PD4
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #92 background imageLoading...
Page #92 background image
86 ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual
Chapter 7—Commands
O – Options Select
Description is command is used to enable or disable various sensors and
the cutter.
Syntax O[S[,N[,D[,Cnnn|Cb]]]]
Parameters S Enable reverse gap sensing.
N Disable label taken sensor.
D Disable ribbon end sensor
Cnnn Print nnn labels (1-255) before cutting.
Cb Print batch before cutting.
Parameters can be entered in any order. Default: ON
Remarks S: Reverse Gap Sensing Enabled
is parameter reverses the operation of the label gap sensor so
it interprets a blockage of light as a gap between labels or similar.
Before using the S parameter, make sure to load the EasyCoder
PD4 printer with the appropriate type of media. By default, the
sensor will interpret blockage of light as a label or similar.
N: Label Taken Sensor Disable
When the label taken sensor is enabled, the communication to
the printer will be BUSY as long as the sensor detects a label in
the outfeed slot. (Does not work with a cutter—use ON to dis-
able the sensor.)
D: Ribbon End Sensor Disable
e ribbon end sensor (thermal transfer models only) detects
reflections from the trailing silvery part of the transfer ribbon.
Direct ermal Mode: If the ribbon end sensor is disabled
parameter, density settings (see D command) are interpreted via a
table that gives an optimized printout for direct thermal printing.
ermal Transfer Mode: If the ribbon end sensor is enabled, an
error will occur if no reflection is detected. e density settings
(see D command) are interpreted via a table that gives an opti-
mized printout for thermal transfer printing.
C: Cutter Enabled
If option C is enabled, cutting will be performed after print.
Commands JF and JB will be disabled, but their values will
remain stored in memory.
If option C is disabled, no cutting will be performed after print.
Commands JF and JB will be enabled. Command f will be dis-
abled but its value will remain stored in memory.

Table of Contents

Other manuals for Intermec EasyCoder PD4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PD4 and is the answer not in the manual?

Intermec EasyCoder PD4 Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder PD4
CategoryLabel Maker
LanguageEnglish

Related product manuals