ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual 45
Chapter 7—Commands
Remarks If parameter www (max. print width) gives less space than
required by the sum of parameters x- (module width) and l-
(max. column count), error condition 50 will occur.
Likewise, if parameter hhh (max. print height) gives less space
than required by the sum of parameters y- (set bar height) and
r- (max. row count), error condition 50 will also occur.
Example
N
b40,40,P,400,300,p40,340,20,f1,x3,y10,r60,
l5,"ABCDEFGHIJK1234567890abcdefghijk"
P1
Note: e last parameter in the b command above (l5) is
lowercase L + the digit 5, not 15!