SECTION 9 " Extended Commands
9-10 VT220/ANSI Terminal Emulation Programmers Reference Guide
Following is an example of data transmitted and received
on the wireless stations RS-232 port. A space and # char-
acter start and end the data.
Column Character Description
1 (Space) This column typically contains a
space.
2 # Extended command.
3 F Transmit and Receive command.
4 4 9600 baud.
5 N No parity.
6 8 Eight data bits.
7 1 One stop bit.
8 0 No CTS flow control.
9 0 No DTR flow control.
10 0 No XON/OFF flow control.
11--12 00 No flow control timeout value.
13--14 50 Receive a maximum of 50
characters.
15--16 0A Delimiter character is 0A
hexadecimal (line feed).
17--18 01 Data will be sent to host after one
delimiter character has been
received.
19--20 02 Start character is 02 hexadecimal
(STX).
21 (Space) Start character will not be
returned.
22 (Space) Do not flag parity errors.
23--24 10 Receive timeout length is 10
seconds.

Table of Contents