SECTION 9 " Extended Commands
9-44 VT220/ANSI Terminal Emulation Programmer’s Reference Guide
Column Character Description
1 (Space) This column typically contains a space.
2 # Extended command.
3 S Scan Bar Code Parameter command.
4 0 No Control Byte 1 options are re-
turned.
5 7 [ENTER] key terminates all scans,
12-volt
laser is enabled, Modulo 10 Check
Digit.
6 F Barcode type is returned and concate-
nated.
7--8 32 Maximum length is 32 characters.
9--10 01 Minimum length is 1 character.
11 2 Decode UPC System 0.
12 2 EAN is enabled.
13 1 Encoded code 39 is enabled.
14 1 Plessey is enabled.
15 1 Mod 10 first digit is checked.
16 2 ABC Codabar is enabled.
17 0 Code 11 is disabled.
18 0 Code 93 is disabled.
19 1 Code 128 is enabled.
20 2 Straight 2of5 is enabled.
21--22 08 Straight 2of5 maximum length is 8.
23--24 01 Straight 2of5 minimum length is 1.
25--26 08 Straight 2of5 1st fixed length is 8.
27--28 08 Straight 2of5 2nd fixed length is 8.
29 0 Interleaved 2of5 is disabled.
30--31 (Spaces) No change from current setting.
32--33 (Spaces) No change from current setting.
34--35 (Spaces) No change from current setting.
36--37 (Spaces) No change from current setting.