Goodrive300-LIFT series inverter Fault tracking
-97-
Code
Fault
Possible cause
Solution
transients is too strong
the torque lift
OL2
Inverter overload
The acceleration is too
fast
Reset the rotating motor
The voltage of the power
supply is too low.
The load is too heavy.
Close loop vector control,
reverse direction of the
code panel and long
low-speed operation
Increase the ACC time
Avoid the restarting after
stopping.
Check the power of the
supply line
Select an inverter with
bigger power.
Select a proper motor.
SPI
Input phase loss
Phase loss or fluctuation of
input R,S,T
Check input power
Check installation
distribution
SPO
Output phase loss
U,V,W phase loss input(or
serious asymmetrical three
phase of the load)
Check the output
distribution
Check the motor and cable
OH1
Rectifying module
overheated
Air duct jam or fan
damage
Ambient temperature is
too high.
The time of overload
running is too long.
Redistribute dredge the
wind channel or change the
fan
Low the ambient
temperature
OH2
IGBT overheated
EF
External fault
SI external fault input
terminals action
Check the external device
input
CE
485 communication
fault
The baud rate setting is
incorrect.
Fault occurs to the
communication wiring.
The communication
address is wrong.
There is strong
interference to the
communication.
Set proper baud rate
Check the communication
connection distribution
Set proper communication
address.
Change or replace the
connection distribution or
improve the
anti-interference capability.
ItE
Current-detecting
fault
The connection of the
control board is not good
Hoare component is
Check the connector and
repatch
Change the Hoare

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT GD300L Series and is the answer not in the manual?

INVT GD300L Series Specifications

General IconGeneral
BrandINVT
ModelGD300L Series
CategoryInverter
LanguageEnglish

Related product manuals