EasyManua.ls Logo

INVT GD300L Series

INVT GD300L Series
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive300-LIFT series inverter Function parameters
-57-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P07.61
Output terminals
state at last but
one fault
0
P07.62
Reserved
065535
0
P07.63
Reserved
065535
0
P08 Group Enhanced function
P08.00
Analogic
weighing input
0: None
1: AI1
0
P08.01
Pre-torque offset
0.0100.0%
45.0%
P08.02
Gain at drive
side
0.0007.000
2.000
P08.03
Gain at braking
side
0.0007.000
2.000
P08.04
Brake close
delay
0.005.00s
0.10s
P08.05
Brake switch-off
delay
0.005.00s
0.10s
P08.06
Brake feedback
detection time
0.05.0s
2.0s
P08.07
Brake fault
action
0: Report the fault and stop
1: Stop without fault reporting
0
P08.08
Contactor
feedback
detection time
0.005.00s
2.0s
P08.09
Contactor fault
action
0: Report the fault and stop
1: Stop without fault reporting
0
P08.10
Braking
threshold
voltage
320.0750.0V
700.0V
P08.11
Auto fault reset
count
010
(OUT and OC do not allow auto fault reset.)
0

Table of Contents

Related product manuals