Goodrive300-LIFT series inverter Function parameters
-35-
the password can be canceled. If P07.00 is not 0 during powering on, then the parameter is protected
by the password. When modify parameters by serial communication, the password function also
follows the above rules.
Detailed instruction of parameters
P00 Group Basic function group
0: Sensorless vector control (SVC) mode 0
1: SVC mode 1
2: V/F control
3: Closed-loop vector control
0: Keypad ("LOCAL/REMOT" off)
1: Terminal ("LOCAL/REMOT" blinking)
2: Communication ("LOCAL/REMOT" on)
3: CAN ("LOCAL/REMOT" on)
0: Keypad
1: AI1
2: AI2
3: Multi-step speed running
4: Remote communication
5: AI1 tracking running
6: CAN communication-based setting
7: CAN communication-based reference
0–P00.02 (lift rated speed)
0: Default direction
1: Reverse direction
2: Forbid to run in reverse direction
0: Fixed carrier frequency, set by P00.08
1: Auto adjustment