Goodrive300-LIFT series inverter Function parameters
-59-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P08.25
Enable short
floor control
0: Disable
1: Enable
0
P08.26
Short floor
speed
0.0%90.0% (P00.02)
40.0%
P08.27
Short floor
running time
0.0020.00s
200
P08.28
Contactor
disconnection
delay
0.0010.00s
2.00s
P08.29
Enable Keb
sequence
0: Disabled
1: Enabled
0
P08.30
Open-loop start
brake open
frequency of
asynchronous
motor
0.005.00 Hz
0.00 Hz
P09 Group Speed curve setting
P09.00
Multi-step speed
0
0.000P00.02
0.000m/
s
P09.01
Multi-step speed
1
0.000P00.02
0.000m/
s
P09.02
Multi-step speed
2
0.000P00.02
0.000m/
s
P09.03
Multi-step speed
3
0.000P00.02
0.000m/
s
P09.04
Multi-step speed
4
0.000P00.02
0.000m/
s
P09.05
Multi-step speed
5
0.000P00.02
0.000m/
s
P09.06
Multi-step speed
6
0.000P00.02
0.000m/
s
P09.07
Multi-step speed
7
0.000P00.02
0.000m/
s