Loading...
Goodrive300-LIFT series inverter Function parameters
-60-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P09.08
Multi-step speed
priority
0: CHINESE TYPE
1: ISTANBUL TYPE
2: KONYA TYPE
3: ADANA TYPE
0
P09.09
S-curve ACC
start segment
duration
0.1360.0s
2.0
P09.10
S-curve ACC
end segment
duration
0.1360.0s
2.0
P09.11
ACC time
0.1360.0s
2.0
P09.12
S-curve DEC
start segment
duration
0.1360.0s
2.0
P09.13
S-curve DEC
end segment
duration
0.1360.0s
2.0
P09.14
DEC time
0.1360.0s
2.0
P09.15
S-curve start
segment
duration during
stop
0.1360.0s
2.0
P09.16
S-curve end
segment
duration during
stop
0.1360.0s
2.0
P09.17
Running speed
at maintenance
0.001 P00.02
0.200m/
s
P09.18
ACC/DEC time
at maintenance
0.1360.0s
4.0s
P09.19
Forced DEC
time
0.1360.0s
2.0s
P09.20
Emergency
running speed
0.001 P00.02
0.100
m/s
P09.21
Emergency
ACC/DEC time
0.1360.0s
20.0s
P09.22
Leveling
segment
07
0
P09.23
Leveling speed
0.001 P00.02
0.010m/
s

Table of Contents

Related product manuals