EasyManuals Logo

INVT GD300L Series User Manual

INVT GD300L Series
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
Goodrive300-LIFT series inverter Function parameters
-61-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P09.24
DEC time for
creeping to stop
0.1360.0s
During deceleration to stop, when the speed
reached the value set in P01.12, the curve of
deceleration to stop switches to those set in
P09.15, P09.16, and P09.24.
2.0s
P09.25
Speed threshold
for light-load
detection in
open-loop
control
5.0020.00 Hz
5.00 Hz
P10 Group Non-weighing compensation
P10.00
Enable
non-weighing
compensation
0: Disable
1: Enable
0
P10.01
Load
compensation
time
0.0005.000s
0.400
P10.02
Load
compensation
decrease time
0.0005.000s
0.100
P10.03
Load
compensation
ASR gain
0100.0
25.0
P10.04
Load
compensation
ASR integral
time
0.0110.000s
0.160
P10.05
Load
compensation
current
coefficient KP
01000
1000
P10.06
Load
compensation
current
coefficient KI
01000
0
P10.07
APR gain
0100.0
0.0
P10.08
APR integral
time
0.00110.000s
0.001