Goodrive300-LIFT series inverter Function parameters
-45-
Detailed instruction of parameters
speed of the motor and its function code is
P02.03; p is the pole pair of the motor. 100.0%
corresponds to the rated slip frequency△f.
Setting range: 0.0–200.0%
Motor vibration
control factor at
low frequency
Motor vibration
control factor at
high frequency
Motor vibration
control threshold
In SVPWM control mode, current fluctuation
may occur to the motor at some frequency,
especially the motor with big power. The motor
cannot run stably or overcurrent may occur.
These phenomena can be canceled by adjusting
this parameter.
Setting range of P04.03: 0–100
Setting range of P04.04: 0–100
Setting range of P04.05: 0.00Hz–P00.04 (max.
output frequency)
0: No operation
1: Automatic energy-saving operation (reserved)
Integral in SM
MTPA control
P05 Group Input terminals
0: High-speed pulse input. See P05.27–P05.31.
1: Digital input. See P05.12.
0: No function
1: Running up (FWD)
2: Running down (REV)
3: Running in inspection mode (EXM)
4: Emergency running (EMER)
5: Coast to stop (FSTP)