Goodrive300-LIFT series inverter Function parameters
-45-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
speed of the motor and its function code is
P02.03; p is the pole pair of the motor. 100.0%
corresponds to the rated slip frequencyf.
Setting range: 0.0200.0%
P04.03
Motor vibration
control factor at
low frequency
0100
10
P04.04
Motor vibration
control factor at
high frequency
0100
10
P04.05
Motor vibration
control threshold
In SVPWM control mode, current fluctuation
may occur to the motor at some frequency,
especially the motor with big power. The motor
cannot run stably or overcurrent may occur.
These phenomena can be canceled by adjusting
this parameter.
Setting range of P04.03: 0100
Setting range of P04.04: 0100
Setting range of P04.05: 0.00HzP00.04 (max.
output frequency)
30.00
Hz
P04.06
Energy-saving
operation
0: No operation
1: Automatic energy-saving operation (reserved)
0
P04.07
Gain in SM
MTPA control
0~3000
50
P04.08
Integral in SM
MTPA control
0~3000
30
P05 Group Input terminals
P05.00
HDI input
selection
0: High-speed pulse input. See P05.27P05.31.
1: Digital input. See P05.12.
0
P05.01
S1 function
selection
0: No function
1: Running up (FWD)
2: Running down (REV)
3: Running in inspection mode (EXM)
4: Emergency running (EMER)
5: Coast to stop (FSTP)
1
P05.02
S2 function
selection
2