Goodrive300-LIFT series inverter Function parameters
-62-
Detailed instruction of parameters
Current loop
filter coefficient
Bit0–2: Current instruction filter count
(compensation completion phase)
Bit3-5: Current instruction filter count
(compensation phase)
Bit6: Speed detection switching( 0:
segmentation; 1 observer)
Bit7-8: Current sampling filter count
Bit14: Enable temperature-based carrier
frequency decrease (0: Enable; 1: Disable)
Bit2–15: Reserved
P11 Group Protective parameters
0x000–0x111
LED ones:
0: Disable input phase loss protection
1: Enable input phase loss protection
LED tens:
0: Disable output phase loss protection
1: Enable output phase loss protection
LED hundreds:
0: Disable hardware input phase loss protection
1: Enable hardware input phase loss protection
Frequency-decre
asing at sudden
power loss