Goodrive300-LIFT series inverter Function parameters
-58-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P08.12
Faulty relay
action during
auto fault reset
0x000x11
LED ones:
0: Action during undervoltage
1: No action during undervoltage
LED tens:
0: Action during auto fault reset
1: No action during auto fault reset
0x00
P08.13
Auto fault reset
interval
0.1100.0s
0.1s
P08.14
Braking
frequency during
stop
0.005.00Hz
0.00Hz
P08.15
Inverter stop
delay
0.005.00s
0.10s
P08.16
Current
withdrawal time
during stop
0.005.00s
0.20s
P08.17
Modulation
0: 2PH modulation
1: 3PH modulation
1
P08.18
Overmodulation
validity
0: Invalid
1: Valid
1
P08.19
FDT1 electrical
level detection
value
0.00P00.04 (max. frequency)
0.20Hz
P08.20
FDT1 lag
detection value
0.0100.0% (FDT1 electrical level)
0.0%
P08.21
Frequency
arrival detection
amplitude
0.00P00.04 (max. frequency)
0.00Hz
P08.22
Cooling fan
running mode
0: Normal mode
1: The fan keeps running after power on
0
P08.23
Enable light-load
direction search
0: Disabled
1: Enable auto running
2: Enable the function of providing the running
direction
0
P08.24
Light-load
direction
detection time
0.0005.000s
2.000s

Table of Contents