Goodrive300-LIFT series inverter Function parameters
-71-
Detailed instruction of parameters
Display the rotation speed of the motor.
Setting range: 0–65535RPM
Display current torque current of the inverter.
Setting range: -3000.0–3000.0A
Display current exciting current of the inverter.
Setting range: -3000.0–3000.0A
Display current power of the motor.
Setting range: -300.0–300.0% (relative to the
motor rated power), 0.0% (relative to the motor
rated power)
Display the current output torque of the inverter.
Setting range: -250.0–250.0%%
Evaluated motor
frequency
Evaluate the motor rotor frequency on close loop
vector.
Setting range: 0.00–P00.04
Display current DC bus voltage of the inverter.
Setting range: 0.0–2000.0V
Digital input
terminals state
Display current Switch input terminals state of
the inverter.
Digital output
terminals state
Display current Switch output terminals state of
the inverter.
Display analog AI1 input signal.
Setting range: 0.00–10.00V
Display analog AI2 input signal.
Setting range: 0.00–10.00V
Display HDI input frequency.
Setting range: 0.000–50.000kHz