Service functions and error messages
Page 128
Meaning of the error message
2 PROFIBUS:
communication error
Check the slave address.
Check the bus terminators.
Check the cabling.
3 PROFIBUS:
invalid slave address
Incorrect slave address. Please
select another slave address.
4 PROFIBUS: error in value range Mathematical error during the conversion of physical units.
The value range of the data and of the physical units do not
match (fieldbus display units).
If necessary, contact the Technical Support.
23 0 No consumable record Position save and restore failed, homing required.
1 Record with invalid checksum
2 Flash content inconsistent
25 0 Invalid device type Please return the device to our sales partner.
1 Device type not supported
2 HW revision not supported Check the firmware version.
If necessary, request an update from the Technical Support.
3 Device functionality restricted! Please return the device to our sales partner.
4 Invalid power module type Check the firmware version.
If necessary, request an update from the Technical Support.
5 Incompatibility firmware / hardware.
The firmware is not suitable for the
device.
Check the firmware version.
If necessary, request an update from the Technical Support.
26 0 No user parameter set Load the default parameter set.
1 Checksum error If the error is still present, return the device to our sales
partner.
2 Flash: write error Please return the device to our sales partner.
3 Flash: delete error
4 Flash: error in the internal flash Reload the firmware.
If necessary, contact the Technical Support.
5 No calibration data
6 No user position data set Save and reset.
Load the default parameter set.
If the error occurs again, contact the Technical Support.