Service functions and error messages
Page 130
Meaning of the error message
6 DC bus circuit discharge time exceeded
Bridge for the internal brake resistor installed?
Check the connection of the external braking resistor.
If necessary, contact the Technical Support.
7 No power supply for the controller
enable signal
No DC bus circuit voltage?
Check the power supply.
If necessary, contact the Technical Support.
8 Power supply failure during the
controller enabling process
Check the power supply.
9 Phase failure
33 0 Following error, encoder emulation Check the settings of the incremental encoder emulation
(number of lines).
If necessary, contact the Technical Support.
34 0 No synchronisation via the field bus Failure of synchronization messages from master?
1 Field bus synchronisation error Failure of synchronization messages from master?
Insufficient synchronisation interval?
35 0 Overspeed protection of the linear
motor
The encoder signals are disturbed. Check the installation for
compliance with EMC recommendations.
5 Error during the determination of the
commutation position
The selected method is not suitable for the motor. Please
contact the Technical Support.
36 0 Parameter limited Check the user parameter set.
1 Parameter not accepted
40 0 Negative SW limit switch reached Check the negative range limit.
1 Positive SW limit switch reached Check the positive range limit.
2 Target position beyond the negative
SW limit switch
The start of a positioning run has been suppressed, since the
target is located beyond the respective software limit switch.
Check the target data.
Check the positioning range.
3 Target position beyond the positive SW
limit switch
41 0 Path program: synchronisation error Check the parameterization.
If necessary, contact the Technical Support.