Chapter 6
Controller V6 Touch
Page 102 DM55 DynaDrum PP V6, Manual No.21-18, Rev.2.19
XIO Template Settings, Module #1
To go to this screen, press the XIO Settings button on the Settings Screen.
Item Description
1
• This feature is needed when reactive adhesives (PUR) are used. It will control an optional
valve to purge the adhesive.
• When this feature is enabled: every time the pump is started the PUR-purge valve is
opened for an adjustable duration ( = Purge Time)
• This option requires V6-XIO revision B or higher.
2
• In normal operation the air inject function helps to separate the platen from the adhesive
surface when the platen is moved upwards and after 5 seconds the purge valve
automatically opens to equalize the pressure below the platen to the ambient air pressure.
• In some cases it might be necessary to use the air inject pressure for a longer time to assist
in raising the platen out of the drum.
• When the Platen Lift Assistance is checked, the purge valve will not open after 5 seconds. It
will open once the platen is getting close to leave the drum.
• Default configuration is: Auto Purge not enabled, No Platen Lift Assistance
3 Press the left-pointing arrow to go to the previous XIO Module screen.
4 Press the right-pointing arrow to go to the next XIO Module screen.
5 Press the OK button to confirm your entered values and return to the previous screen.
6 Press the ESC button to discard any non-confirmed values and return to the previous screen.