ITW Dynatec
Chapter 6
Controller V6 Touch
Page 110 DM55 DynaDrum PP V6, Manual No.21-18, Rev.2.19
V6 Power Module PN 823306
Each V6 Power module consists of two identical PCBs which together provide controlled
power to the heaters of eight zones. It receives its control signals from the V6 TEMP
module. Depending on the configuration of the ASU, there may be several V6 Power
modules in the system. Connections are made to both sides of the module.
The fuses are located underneath a protective cover. The cover should only be removed
after the ASU is switched Off and disconnected from the main power supply. After
checking or replacing fuses, the cover must be re-installed. All heater circuits are fused
on both legs with a 10A fuse. Always replace fuses with the same type of fuse. The
maximum total load current of the board is 40 Amps (20 per phase).
Head
Heater
Hose
Heater
Head
Heater
Hose
Heater
Voltage
Supply
Fuses (under
protective cover)
Connect to
V6 TEMP Module
Connect to
V6 TEMP Module
Not used in this configuration
Not used in this configuration