ITW Dynatec
Chapter 3
Description and Technical Specs
Page 22 DM55 DynaDrum PP V6, Manual No.21-18, Rev.2.19
Two-Hand-Control-Buttons (Left & Right-Confirm-Buttons)
The platen will not move until the two-hand (mechanical) buttons are depressed
simultaneously. This prevents the operator from placing one or more of their own hands
and/or arms at the pinch point between the platen and the drum of adhesive.
See Chapter 5.2 Setting-up operation.
System Status Lights
The stack lights ease remote monitoring of the system’s
status. They are mounted on top of the panel box
assembly.
On t
he tri-color stack light, the lower, green light
illuminates when the system has warmed up to
temperature setpoints.
The middle, amber light illuminates when the level of
material in the drum is low. This is the operator’s
signal that a fresh drum of adhesive will soon be
needed.
The upper, red light illuminates when the drum is
empty or there is an alarm condition and is
accompanied by an audible alarm.
The horn is housed within the upper (black) section of
the stack.
Mechanical High-Temperature Protection
The Bulk Melter includes a mechanical (redundant) over-temperature thermostat that acts
as a safety backup. If the unit’s manifold temperature should exceed 232°C (450°F), the
thermostat will cause the Melter’s circuit breaker to open and power to the manifold,
platen, valve heater and hose(s) will be cut off. The mechanical thermostat automatically
re-sets after the manifold temperature falls below 204°C (400°F).
RTD Sensors
The standard Dynamelt system uses 100-ohm platinum resistance temperature detector
sensors for all temperature controls.
Black:
Audible alarm
Red:
E
mpty drum or any
alarm condition
Am
ber:
Low material level
Gr
een:
System ready