Setting-up Operation, Daily Operation
Page 44 DM55 DynaDrum PP V6, Manual No.21-18, Rev.2.19
5.3 Switching the unit off
CAUTION! RISK OF BURNS AND INJURY!
Parts of the unit can be hot long after switching off.
Always wear heat-resistant protective gloves and safety goggles!
Molten adhesives at operating temperature could cause severe burns.
Do not touch the hot surfaces or parts without wearing heat-resistant
protective gloves!
Do not switch off the controller and the main switch, if the unit has to be operated
by weekly timer.
Execute following steps for switching the unit off:
1. Switch all pumps respectively motors off.
2. Switch the controller off.
3. Switch the main switch off!
Removing dirt:
Remove dirt from all unit components immediately.
Wooden scrapers, lint-free cloth with cleaner may only be used for cleaning.
Metallic scrapers or other tools made from steel, like knife or blades, may not be used
under any circumstances.