Chapter 5
Setting-up Operation, Daily Operation
ITW Dynatec
DM55 DynaDrum PP V6, Manual No.21-18, Rev.2.19 Page 43
CAUTION
Be sure that the hose(s) are free to move with the platen.
DO NOT allow the drum to rise with the platen as it may cock off center and be
difficult to remove.
DO NOT attempt to raise or lower platen unless platen is at operating temperature.
4. Slide the drip tray (optional) onto the drip tray rails.
5. Open the clamshell and slide the empty drum out of the unit.
WARNING HOT SURFACE
DO NOT grasp the drum by its lip as severe burns from molten material may occur.
WARNING
EYE PROTECTION & PROTECTIVE CLOTHING REQUIRED
Always wear safety eye protection, protective gloves and long-sleeved
clothing when working on or operating the unit.
Keep away (your hands, head, etc.) from platen and piston pump!
Limbs may be drawn in. Risk of crushing!
Proceed as described under Chapter Bulk Melter Startup Procedureon previous
pages starting from step 15.