Chapter 4
Installation
CAUTION
Before setting up, please read this documentation carefully.
DO NOT operate the Melter in an ambient temperature of less than 32°F (0°C) or
higher than 113°F (45°C).
Pay attention to all the installation and connecting advices.
Heed all safety instructions mentioned in chapter 2.
4.1 Conditions for set-up and mounting
Place requirement
Install the Bulk Melter so that the operator is able to work on it from all sides, for e.g. for
adjusting, preparing, maintaining, repairing, cleaning, etc. See drawing of the unit for
admeasurements.
Mounting and alignment
The complete unit has to be set up on solid, stable and flat ground.
The alignment in height of the complete system has to be considered.
The alignment of the machine has to be considered.
Electrical connection
Necessary electrical connection has to be provided. See electrical schematics.
Electrical power is connected to the upper disconnect circuit breaker terminals located
in the control panel box. A conduit opening must be customer-provided in the panel
box for the power leads.
Never connect or disconnect plug-and-socket connections under load!
Pneumatic connection
Provide the necessary pneumatic connection. 80 psi (5.5 bar) minimum air pressure is
required.
Air pressure is supplied through a 1/2” NPT fitting located at the pneumatic control
panel. The air supply line should be a minimum of 1/2”. Air pressure requirements are
80 psi minimum of clean, dry air. Optional air dryers are available.
In any case the air has to be clean and dry! See advice in chapter 4.3 „Quality of
compressed air“.
Please heed that units with high air demand may not be used at the same time with
the same air supply.
Advices:
Check all screw connections at the unit and retighten if necessary.
Lay the cables and heated hoses so that no risk or least possible risk of stumbling
occurs.