Chapter 6
Controller V6 Touch
Page 58 DM55 DynaDrum PP V6, Manual No.21-18, Rev.2.19
Pump Control Screen/ Linear Line Speed
To go to this screen, press the Pump 2 field on the Pump Overview screen (to go to the Pump 1,
etc. Control screen, press the corresponding field). Then press the Settings button, select Linear
Line Speed in the Current Pump Mode menu on the Extended Pump Mode Settings screen and
then press the BACK button.
The Pump Control Linear Line Speed screen allows you to program the Auto Mode Settings (Set
point minimum/maximum RPM at 0–10VDC external signal control) and Manual Mode Settings
(Manual Set point RPM).
Pump 1 Example at DM55 with Gear Pump:
Item Description
1
Pump #1 is the selected pump. All the settings and speeds displayed on this screen
correspond to Pump #1.
2
Press the according switch for pump control. The activated switch is highlighted green.
• Use Master Pump Control: The selected pump will use the START/STOP signal and the
0-10V speed signal that pump #1 uses.
• Use Independent Pump Control: The selected pump will use its own START/STOP
signal and 0-10V speed signal.
3
Setpoint
The minimum and maximum setpoint values of the pump are displayed. The programmable
range is 0 to 90 rpm or 0 to 100%.
By pressing the input field you can edit the RPM or % values.
4
Manual Setpoint
The manual setpoint value of the pump is displayed.
By pressing the input field you can edit the value.