Chapter 6
Controller V6 Touch
ITW Dynatec
DM55 DynaDrum PP V6, Manual No.21-18, Rev.2.19 Page 57
Item Description
1
Pump Overview
SETTINGS: Press Pump 1, Pump 2, etc. to go to the appropriate Pump Control screen.
MANUAL: The pump speed is adjusted manually by the ASU operator. When selected the
MANUAL icon is highlighted green.
STOP: The pump is stopped, until AUTO or MANUAL is selected. When selected, the
STOP icon is highlighted red.
AUTO: The pump speed is controlled via a 010VDC signal that is provided by an external
device (pattern control equipment or parent machine input). When selected, the AUTO icon
is highlighted green.
Auto operating parameters for each Pump must be set on the Pump Control Screen.
STATUS: Indicates the pump status.
See icons line/description at the bottom of the screen.
- Stop Mode = Pump is stopped.
- Low Temp. = Melter has not reached setpoint temperature.
- Enable Missing = Pump enable signal is missing from customer contact.
- Pump Running = Pump is running.
RPM: The actual (calculated) RPM of each pump will be displayed.
PRESSURE: The pressure for each pump (if available) will be displayed. See explanation
under Main Screen point 4.
COMMENT = The entered pump name will be displayed.
2
All Pumps Buttons
Press one of the All Pumps buttons (either MANUAL, STOP or AUTO) to set all pumps to the
desired function at one time.
3
BACK Button
Press to return to the previous screen.
4
Pressure Discrepancy Alarm:
If the display fields are highlighted red, it indicates that the (optional) pressure discrepancy has
detected an excessive difference between the primary and secondary pressure. See point
“Extended Pump Mode Settings Screen, Linear Line Speed, Pressure Control” for further
information.