Chapter 6
Controller V6 Touch
Page 82 DM55 DynaDrum PP V6, Manual No.21-18, Rev.2.19
Level Control Settings
To go to this screen, press the General Settings button on the Settings Screen.
Item Description
1
Parameter Selection tabs
The Level Control Settings tab has been selected.
2
Empty Level
If fill level is lower than this parameter an empty message will be generated.
3
• This is a programmable time delay for reappearance of the level control’s Empty message.
The level control device informs the operator via a "Minimum Level" message on the display
that the drum needs to be changed. After expiration of the time delay, the message
Minimum Level will be indicated on the display. The programmable range is 0-31 minutes.
• If alarm is not acknowledged in between 5 minutes the pump will come to a standstill.
• Touch a zone input box and a numeric entry keypad will appear and the values can be
edited. Enter the value and confirm by pressing OK.
4
This is the drum low level.
An orange alarm light will indicate when level falls below this value.
5
Switch Level (Start)
If system is configured as refiller control this parameter defines the refill start level.
6
Switch Level (Stop)
If system is configured as refiller control this parameter defines the refill stop level.
7
Alarm Level (Max)
Template-dependent parameter (not used in standard configuration).
8 Press the left-pointing arrow to go to the previous General Settings screen.
9 Press the right-pointing arrow to go to the next General Settings screen.