Temperature Zones Set Screen
To go to this screen, press the Set/Act button on the Main Screen.
The Set screen allows you to program the set point temperature for each activated zone. Each
zone requires a temperature set point.
When a temperature zone is not used, it can be de‐activated (turned OFF) on the Heating Priority
screen. A zone that is turned Off no longer heats and is not monitored by the controller for over or
under temperatures.
Item Description
1
• Display of the temperature set point values.
• To edit values: Touch a zone input box and a numeric entry keypad will appear. Enter your
new set point value and confirm by pressing OK.
NOTE: Must be below the maximum set point value listed below.
• The Set values are displayed for about 15 seconds and, if there is no display activity, the
display returns automatically to the Actual values.
• The maximum set point value is 218°C (424°F).