Chapter 5
Setting-up Operation, Daily Operation
DM55 DynaDrum PP V6, Manual No.21-18, Rev.2.19 Page 35
Description/ Location Function Indication
Gauge on pneumatic control panel
(PCP), regulator in pneumatic panel
box (PPB)
Regulators adjust force to
raise (Ram Up) and lower
(Ram Down) the platen
Right: increases pressure
Left: decreases pressure
Recommended setting: 40-60 psi
Gauge on PCP, regulator in PPB
Regulator adjusts force of
air injection valve
Right: increases pressure
Left: decreases pressure
Recommended setting: 5 psi
Gauge on PCP & regulator in PPB
Fine-tunes force to raise
the platen
Right: increases pressure
Left: decreases pressure
Recommended setting: 10-12psi
Left & Right-Confirm-
Buttons (Two-Hand-
Control-Buttons)/
2 buttons on sides of PCP
By pressing these switches
simultaneously the platen
will be lowered or lifted
manually or automatically
depending on Auto/Man-
Switch’s position and
Up/Down-Switch’s position.
Flashing arrows on controller
screen indicate direction of
movement.
Air Inject Momentary Button/
Right side of PCP
By manually pressing this
button, air will be injected
into the drum to retract
platen.
The Air Inject is automatically
activated after pressing both Two-
Hand-Control-Buttons (Left &
Right-Confirm-Buttons) for lifting
the platen (in Auto mode and in
manual mode) and it is
automatically deactivated when
platen has reached top position.
Mounted behind PPB
Regulates the incoming air
pressure needed for
operation/ switches from
supply air to exhaust air for
lock-out/ tag-out.
Supply setting: 80 psi (5.5 bar)
minimum.
Controllers/
Below valve assembly
Regulates the speed of the
up and down movement of
the ram cylinders (Note: set
pressures before setting
speeds)
A meter/ out flow control. Set per
your application. Set at initial
installation. (Not intended for
operator’s continued use.)