Engineering manual - UniSAB III 1.10.8
266/346
001930 en 2021.06
Calibration
7.5.8 Adjusting long-stroke capacity rod for SAB 283 Mk 1
For type part no. 1373-038
Note: For long-stroke transmitters with part no. 1373-057 calibration and terminal connection are similar
to that of SAB 110, SAB 128 etc. Please see subsection 7.5.7
As shown in Fig. 36, the capacity transmitter is fitted with a single calibration button surrounded by a
green and red LED.
During normal operation the red LED flashes rather slowly. The green LED is switched on constantly
when the transmitter is in 100% position whereas it flashes quickly when the transmitter is in 0%
position.
Fig. 36: Long-stroke SAB 283 Mk 1
Calibration is carried out as follows:
1. Apply supply voltage minimum five minutes before calibration.
2. Move the slide to minimum position and press the calibration button once. The red LED will
switch ON. After a while, the red LED will turn OFF indicating that it is ready for 100%
calibration.
3. Move the slide to its maximum position and press the calibration button again. The red LED will
start flashing quickly. After a while the red LED will flash normally and calibration is completed.
7.5.9 Adjusting short-stroke capacity rod for Gram GST, GSV and RWF and short-
stroke volume transmitter for GSV, RWF and SAB 283 Mk 1 and SAB 355 Mk 1
For part no. 1373-037
Note: For short-stroke transmitters with part no. 1373-061 calibration and terminal connection are simi-
lar to that of SAB 100, SAB 128 etc. Please see subsection 7.5.7
Fig. 37: Short-stroke
3
2
1
2 =
1 =
3 =
3
74mm
60mm
2
1
Plug connection
Supply, +10 to 32V DC
Common, 0V DC
Out, 4-20 mA
GND
LED digital
output (option)
Calibration
push button
LED supply/operation
Dia
7 mm
1
1=
2=
3=
=
Supply, 24V DC
Common, 0V DC
Out, 4-20 mA
GND
Calibration
push button
LED supply
LED digital output
Plug connection

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls SABROE UniSAB III and is the answer not in the manual?

Johnson Controls SABROE UniSAB III Specifications

General IconGeneral
BrandJohnson Controls
ModelSABROE UniSAB III
CategoryControl Systems
LanguageEnglish

Related product manuals