4-112
4.20.7.5 Setting Contact Output 1
· The following contact outputs can be set for contact output 1: System, System + XTD + ARV,
Log Pulse (200 pulse/NM), Log Pulse (400 pulse/NM), and Alarm ACK.
· Please refer to "6.3 Cable Connection" for connection.
The following is an overview of the contact output 1 submenu.
· SYSTEM: A contact is made when the No positioning fixing alarm occurs.
· SYS+XTD+ARV: A contact is made when No positioning fixing, XTD / boundary, or arrival /
anchor alarms occur.
· 200p/NM: 200 pulse/NM LOG pulse is output.
· 400p/NM: 400 pulse/NM LOG pulse is output.
· ALARM ACK: Operates as an ACK when an alarm has been generated by externally
connected equipment.
1. Please refer to "4.20 Equipment Configuration" and switch the unit to equipment
configuration mode.
2. Press
, and then to select "CONTACT OUT1".
3. Select the state for which you want contact operation with , and then press
.
4.20.7.6 Setting Contact Output 2
· The following contact outputs can be set for contact output 2: System, System + XTD + ARV,
Log Pulse (200 pulse/NM), Log Pulse (400 pulse/NM), and Alarm ACK.
· Please refer to "6.3 Cable Connection" for connection.
1. Please refer to "4.20 Equipment Configuration" and switch the unit to equipment
configuration mode.
2. Press
, and then to select "CONTACT OUT2".
From this point on, operation is identical as that described for "CONTACT OUT1".
Procedure